| Brand Name: | FGB_Humidifier-Vicks |
| Model: | Model EBSV2013 |
| Affected: | Euky Bear (Warm Steam) Vaporiser - Humidifier - Batch Numbers: 230301, 231101, A231101 and 8231101 |
| Software version: | |
| Recalling Organisation: | CARSL Consulting 30 Fulford Road Havelock North 4130 Hastings |
| Contact Information: | 09 238 3447 |
| Manufacturer: | Felton Grimwade & Bosisto's Pty Ltd |
| Issue: | The manufacturer has become aware that the enclosed heating element for these batches is overheating. If users allow the device to run dry (ie don't turn the device off after steaming is complete as directed in the IFU), this can cause the heating module polymer housing to disintegrate. This may result in the device producing smoke or fumes. If the heating module finger is exposed, it could cause burns. |
| Recall action type: | Recall |
| Recall action: | Product to be returned to supplier |
| Level of recall: | Hospital/Pharmacy/Laboratory |
| Date Commenced: | 12/9/2023 |
| Additional Information: | www.medsafe.govt.nz/hot/RecallActionNoticesNew/31811.asp |